Xerox 8850 Service Manual page 153

Hide thumbs Also See for 8850:
Table of Contents

Advertisement

5.
(Figure 7): Reinstall the Top Shield, taking care not to overtighten the screws.
2
Reinstall the
screws (2)
Figure 7 Reinstalling the Top Shield
6.
(Figure
1): Reinstall the Sump Filter onto the Developer Module.
7.
Reinstall the Developer Module
(REP
8850/ 510DP
3
Tighten the screws (2), being
careful not to drive the screws
through the Top Shield
1
Reinstall the Top
Shield
9.5).
03/2003
4-77
Repairs and Adjustments
REP 9.7