Replacement
CAUTION
Do not rotate the Auger Gears individually more than the slight amount required for removal or
to mesh the teeth during reinstallation. If the factory setting of the augers is changed during the
procedure, perform the adjustment procedure,
ADJ 9.6
Augers.
NOTE: Ensure that the gears are reinstalled with the flanges as shown to ensure that all the
gears are secured.
NOTE: To ensure that the Toner Cartridge is correctly engaged in the Drive Plate, rotate the
cartridge in both directions until the gears rotate correspondingly.
NOTE: The Developer Module must be kept in the same relative position as it is being
removed the Printer. Excessive rotation or lateral swaying of the module can cause the Devel-
oper material to shift, resulting in diagnostic or image quality faults.
1.
(Figure 5): Reinstall the Pressure Equalizer Tubes.
Repairs and Adjustments
03/2003
REP 9.7
4-74
8850/ 510DP