Rep 10.1 Heat Rod - Xerox 8830 Service Manual

Hide thumbs Also See for 8830:
Table of Contents

Advertisement

REP 10.1 Heat Rod

Parts List on PL 10.2
WARNING
Switch off the Main Power Switch. Disconnect the
Power Cord. Allow the Fuser Assembly to cool
before the procedure is performed.
Removal
1. Remove the Stripper Finger Assembly.
2. Perform the Xerographic Module procedure
(REP 9.1) through Step 11. This will leave the
Xerographic Module at the Service Position,
handles installed, and the Drum Assembly
removed.
NOTE: In the following steps, "Left" and "Right"
describe machine locations as observed when you
are facing the Xerographic Module at the left side of
the Printer.
3. (Figure 1): Disconnect the Heat Rod (Right
Side).
8830
0,
Disconnect the connector
and straighten the Heat Rod
Wire
Remove the bracket
from the grommet
Grommet
Figure 1. Removing the Bracket and Grommet (Right Side)
1/98
4-83
Remove the Heat Rod
Wire from the clamp
Remove the grommet from
the Heat Rod Wire
REP 10.1

Hide quick links:

Advertisement

Table of Contents
loading