ADJ 3.2 Line Current Limit

Purpose
The purpose is to set the Line Service (Input Power) and Billing Type (Billing Meter) configura-
tions according to the customer's requirements.
Check
1.
Enter diagnostics.
2.
Enter code [0261] LINE SERVICE.
3.
(Figure 1): Using the numeric keypad, set the line service current by entering the Current
Limit value from Table 1. The range is 8 to 20 amperes (AMPS).
Figure 1 Setting the Line Service
Table 1 Line Service
Market Area
AC Power Rating
United States/Canada
115 V, 20 Amps (510dp 5 and
7 D-size cpm only)
208 - 240 Volts @ 20 amps
208 - 240 Volts @ 15 amps
European Operations (Com-
220 - 240 Volts @ 16 amps
mon Market)
United Kingdom
220 - 240 Volts @ 13 amps
Switzerland
220 Volts @ 10 amps
Central and South America
220 - 240 Volts @ 20 amps
a.
Press the Enter button in order to store the value in NVM.
b.
Press the Exit button.
4.
Enter code [0263] BILLING TYPE.
5.
(Table 2): Set the Billing Type.
a.
Use the Next or Previous button to change the NOW setting.
b.
Press the Enter button in order to store the value in NVM.
c.
Press the Exit button two times.
Table 2 Billing Type
Selections
Configuration
00
01
METRIC
8850/ 510DP
Current Limit
17.6 amps
17.6 amps
13.2 amps
16.0 amps
13.0 amps
10.0 amps
15. 0 amps
FEET
6.
Exit the diagnostics mode.
03/2003
4-143
Repairs and Adjustments
ADJ 3.2