Rep 10.1 Heat Rod - Xerox 8825 Service Manual

Hide thumbs Also See for 8825:
Table of Contents

Advertisement

REP 10.1 Heat Rod

Parts List on
PL 10.2
Switch off the Main Power Switch. Disconnect the Power Cord. Allow the Fuser Assem-
bly to cool before the procedure is performed.
Removal
1.
Remove the Stripper Finger Assembly.
2.
Perform the Xerographic Module procedure
Xerographic Module at the Service Position, handles installed, and the Drum Assembly
removed.
NOTE: In the following steps, "Left" and "Right" describe machine locations as observed when
you are facing the Xerographic Module at the left side of the Printer.
3.
(Figure
1): Disconnect the Heat Rod (Right Side).
Repairs and Adjustments
REP 10.1
WARNING
(REP
9.1) through Step 11. This will leave the
2
Disconnect the con-
nector and straighten
the Heat Rod Wire
3
Remove the
screw
4
Remove the bracket
from the grommet
Grommet
Figure 1 Removing the Bracket and Grommet (Right Side)
01/02
4-88
1
Remove the Heat
Rod
Wire from the clamp
5
Remove the grommet
from the Heat Rod
Wire
8825/8830 Printer