Gp 7 Nvm Dump Of Adjustable Settings - Xerox 8850 Service Manual

Hide thumbs Also See for 8850:
Table of Contents

Advertisement

GP 7 NVM Dump of Adjustable Settings

The purpose of this procedure is to enable the service representative to access a listing of cur-
rent NVM (Non-Volatile Memory) settings resident in the 8850/510dp Printer. If desired, this
information may be saved to a laptop. This information can be of great value in recreating the
customer's Printer settings in the event of a component failure. Information can also be
recorded in the Service Log.
NOTE: Ensure that the Printer and Controller are powered off prior to beginning this proce-
dure.
1.
Remove the two screws at either side of the Printer Lower Right Side Cover. Tilt the cover
(with Controller attached) backward and gently set the Controller on the floor.
2.
(Figure
1): Connect a null-modem cable between the Serial Port of the laptop and either
the Diagnostic Remote Port of the Printer (if installed) or J611 on the Printer Main PWB.
Figure 1 Serial Port Connection - Printer Main PWB
3.
Access the terminal emulator software on the laptop.
4.
Using the terminal emulator software on the laptop, set the serial port for the following
configuration:
Baud rate: 19,200
1 Stop Bit
No parity
Data bits: 8
5.
Hold down the zero button on the 8850/510dp/510dp Printer Control Panel, and turn on
the Controller and the Printer.
General Procedures
GP 7
6.
Set the terminal emulation program on the laptop for capturing text.
7.
Enter the diagnostic code [0366] and hit the Enter key.
8.
The NVM settings are received by the laptop. Stop the text capture on the laptop. The
NVM settings can be saved to a file on the laptop and used in the future.
Diagnostic
Code
2-63
3-60-2
3-60-2
3-62
6-2-1
6-2-2
6-2-3
7-16-1
7-16-2
7-16-3
7-60
8-9
8-60-1
8-60-2
J611
8-60-3
9-3
9-17-1
9-17-2
9-17-3
9-20
9-21-2
9-21-3
9-21-4
9-21-6
03/2003
6-14
Table 1 NVM Values Printed by GP 7
Default Value
Description
0
BILLING TYPE
0
AREA IN <FEET>
SQUARED
0
LENGTH IN
<FEET>
05
DIAGNOSTICS
TIMEOUT
20
BOND SCALE
ADJUST
20
VELLUM SCALE
ADJUST
20
FILM SCALE
AJUST
1493
1493
1493
00
FILM STACKING
DELAY TIME
001 001
STACKER FULL
DETECTION
10
BOND REG TIME RANGE 0-40
12
VELLUM REG
TIME
13
FILM REG TIME
0.85
LED BAR POWER
RATING
1807
REG ROLLS
BOND
1807
REG ROLLS VEL-
LUM
1807
REG ROLLS FILM
0
RUN TIME
107
V(HIGH)
20
V(LOW)
5.6
CP VOLTS.
0.0
BIAS OFFSET
VOLTAGE
Range of Values
0-Feet
1-Meters
0-50 Minutes
0-40
0-40
0-40
ROLL BOND
ROLL VELLUM
ROLL FILM
0-30 Seconds
1 is ENABLED
RANGE 0-40
RANGE 0-40
0.2-1.50 uW
Hours
VOLTS
VOLTS
8850/ 510DP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

510dp

Table of Contents