Table 1 Status Code Entry Chart
Status
Description
Code
LL-41
Fuser error. LL-41 is displayed
when the Fuser heat does not
exceed 210 degrees F (99 degrees
C) within two minutes.
LL-42
Fuser error
No RAP
The Fuser Heat Roll exceeded the
allowable temperature for more
than 30 seconds. The maximum
temperature is 350 degrees F (177
degrees C).
To reset: switch off, then on, the
Main Power Switch.
LL-45
Fuser temperature error
The Fuser was in full-power warm-
up mode more than 10 minutes.
To reset: switch off, then on, the
Main Power Switch.
LL-50
Power supply error
No RAP
24 VDC Bulk power supply failure.
LL-51
Power On Self Test fault
No RAP
The internal RAM failed POST.
8850/ 510DP
Components
BSD
Ref
If declared at install,
BSD
PL
check the Line Service
10.1
10.3
[0261]
PL
10.2
Thermistor (RT2) or
PL 1.1
(RT3) does not touch
the Fuser Heat Roll.
(RT2) or (RT3) has an
open circuit or a short
circuit to ground.
NOTE: Clean/Replace
the Thermistor (RT2) or
(RT3).
Replace AC Module
Assembly (A1).
Thermistor (RT2) or
BSD
PL
(RT3) has a short cir-
10.1
10.2
cuit.
Fuser Temperature not
set to specification (ADJ
10.1)
Line Current Limit
(ADJ
BSD
PL
3.2) - Line Service is not
10.1
10.3
correct for the electrical
PL
voltage used. Current
10.2
limit set point is too low.
PL 1.1
Check the adjustment.
Thermistor
(RT2)
or
(RT3) does not touch
the Fuser Heat Roll.
Heat Rod (HR2), or the
associated circuit, has
an open or short circuit.
Clean/Replace
the
Thermistors
(RT2)
or
(RT3)
Replace
AC
Module
Assembly (A1).
Main PWB (A3)
BSD
PL 1.1
1.3
LVPS (A5)
Replace Main PWB (A3)
PL 1.1
PL
Status
Description
Ref
Code
LL-52
Power On Self Test fault
No RAP
or
The external RAM failed POST.
LL-53
Power On Self Test fault
No RAP
IOT firmware checksum error.
LL-54
Power On Self Test fault
No RAP
An unknown device failed POST.
LL-55
Power On Self Test LVPS fault
No RAP
The Analog to Digital Converter
(ADC) failed POST
LL-56
Power On Self Test ADC/ DAC
No RAP
(Digital to Analog Converter)
fault
The ADC/DAC failed POST
LL-57
Power On Self Test SCC fault
No RAP
LL-58
Power On Self Test
No RAP
Extra "Return Value" from the
Operating System. Reboot (Power
off / Power On).
LL-60
Power On Self Test NVM Check-
No RAP
sum fault
Try to run [0366} to record the
existing NVM values. Run diagnos-
tic [0360] to reset NVM to the
default values. Manually restore
the required NVM values.
LL-61
Power On Self Test revision
No RAP
level fault
Power the Printer up in diagnostics
and run [0360] to reset NVM to
default values.
LL-71
Fuser Fault - Line voltage out of
No RAP
Range.
- Line voltage during Fuser Calibra-
tion is too low or too high.
- Open circuit in one or both of the
Heat Rods or their associated wir-
ing,
- ACH input is too high or too low
- To reset: switch the Main Power
Switch off, then on,.
03/2003
1-9
Table 1 Status Code Entry Chart
Components
Replace Main PWB (A3)
Replace Main PWB (A3)
Replace Main PWB (A3)
Replace the Main PWB (A3)
Main PWB (A3)
Main PWB (A3)
Main PWB (A3)
Replace the Main PWB (A3)
Replace the Main PWB (A3)
Check that the Line Ser-
vice
(ADJ
3.2) is set to
the correct amperage.
One or both of the Heat
Rod circuits has devel-
oped an open circuit.
Replace the AC Module
Assembly (A1)
Service Call Procedures
Status Code Entry Chart
BSD
PL
Ref
Ref
PL 1.1
PL 1.1
PL 1.1
BSD
PL 1.1
1.2
PL 1.1
PL 1.1
PL 1.1
PL 1.1
PL 1.1
BSD
PL
10.1
10.2
PL 1.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

510dp

Table of Contents