Drive Information - Danfoss VLT DriveMotor FCP 106 Programming Manual

Hide thumbs Also See for VLT DriveMotor FCP 106:
Table of Contents

Advertisement

Parameter Lists
Par.
Parameter description
No. #
14-41
AEO Minimum Magnetisation
14-44
d-axis current optimization for IPM
14-5* Environment
14-51
DC-Link Voltage Compensation
14-55
Output Filter
14-6* Auto Derate
14-61
Function at Inverter Overload
14-63
Min Switch Frequency
Dead Time Compensation Zero Current
14-64
Level
14-65
Speed Derate Dead Time Compensation
6
6
14-8* Options
14-89
Option Detection
14-9* Fault Settings
14-90
Fault Level

6.1.13 15-** Drive Information

Par.
Parameter description
No. #
15-0* Operating Data
15-00
Operating hours
15-01
Running Hours
15-02
kWh Counter
15-03
Power Up's
15-04
Over Temp's
15-05
Over Volt's
15-06
Reset kWh Counter
15-07
Reset Running Hours Counter
15-3* Alarm Log
15-30
Alarm Log: Error Code
15-31
InternalFaultReason
15-4* Drive Identification
15-40
FC Type
15-41
Power Section
15-42
Voltage
15-43
Software Version
15-44
Ordered TypeCode
15-45
Actual Typecode String
15-46
Drive Ordering No
15-48
LCP Id No
15-49
SW ID Control Card
15-50
SW ID Power Card
15-51
Drive Serial Number
15-52
OEM Information
15-53
Power Card Serial Number
15-57
File version
15-59
File name
15-6* Option Ident
15-60
Option Mounted
15-61
Option SW Version
136
®
VLT
DriveMotor FCP 106/FCM 106
Default value
66%
100%
[1] On
[0] No Filter
[0] Trip
[2] 2.0 kHz
[0] Disabled
ExpressionLimit
[0] Protect Option Config.
[3] Trip lock
Default value
0 h
0 h
0 kWh
0 N/A
0 N/A
0 N/A
[0] Do not reset
[0] Do not reset
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
Danfoss A/S © 11/2015 All rights reserved.
4-set-up
Change
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
All set-ups
FALSE
4-set-up
Change during
operation
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conversion
Type
index
0
Uint8
0
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
Conversion
Type
index
74
Uint32
74
Uint32
75
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Int16
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[21]
0
VisStr[21]
0
VisStr[21]
0
VisStr[10]
0
VisStr[40]
0
VisStr[20]
0
Uint8
0
VisStr[16]
0
VisStr[30]
0
VisStr[20]
MG03N202