Info & Readouts; Drive Closed Loop - Danfoss VLT DriveMotor FCP 106 Programming Manual

Hide thumbs Also See for VLT DriveMotor FCP 106:
Table of Contents

Advertisement

Parameter Lists
Par.
Parameter description
No. #
16-66
Digital Output
16-67
Pulse Input #29 [Hz]
16-71
Relay Output [bin]
16-72
Counter A
16-73
Counter B
16-79
Analog Output AO45
16-8* Fieldbus & FC Port
16-80
Fieldbus CTW 1
16-82
Fieldbus REF 1
16-84
Comm. Option STW
16-85
FC Port CTW 1
6
6
16-86
FC Port REF 1
16-9* Diagnosis Readouts
16-90
Alarm Word
16-91
Alarm Word 2
16-92
Warning Word
16-93
Warning Word 2
16-94
Ext. Status Word
16-95
Ext. Status Word 2
16-97
Alarm Word 3
6.1.15 18-** Info & Readouts
Par.
Parameter description
No. #
18-1* Fire Mode Log
18-10
FireMode Log:Event
18-5* Ref. & Feedb.
18-50
Sensorless Readout [unit]
18-51
Memory Module Warning Reason
18-52
Memory Module ID
18-53
Memory Module Function

6.1.16 20-** Drive Closed Loop

Par.
Parameter description
No. #
20-0* Feedback
20-00
Feedback 1 Source
20-01
Feedback 1 Conversion
20-12
Reference/Feedback Unit
20-2* Feedback/Setpoint
20-21
Setpoint 1
20-6* Sensorless
20-60
Sensorless Unit
20-69
Sensorless Information
20-8* PI Basic Settings
20-81
PI Normal/ Inverse Control
20-83
PI Start Speed [Hz]
138
®
VLT
DriveMotor FCP 106/FCM 106
Default value
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 mA
0 N/A
0 N/A
0 N/A
1084 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Default value
0 N/A
0 SensorlessUnit
0 N/A
0 N/A
[1] Enabled
Default value
[0] No function
[0] Linear
ExpressionLimit
0 ProcessCtrlUnit
ExpressionLimit
0 N/A
[0] Normal
0 Hz
Danfoss A/S © 11/2015 All rights reserved.
4-set-up
Change
during
operation
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
4-set-up
Change during
operation
1 set-up
TRUE
1 set-up
FALSE
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
4-set-up
Change
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conversion
Type
index
0
VisStr[4]
0
Int32
0
Uint16
0
Int16
0
Int16
-2
Uint16
0
Uint16
0
Int16
0
Uint16
0
uint16
0
Int16
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
Conversion
Type
index
0
Uint8
-3
Int32
0
uint32
0
VisStr[18]
-
Uint8
Conversion
Type
index
-
Uint8
-
Uint8
-
Uint8
-3
Int32
-
Uint8
0
VisStr[25]
-
Uint8
-1
Uint16
MG03N202