Parameters
14-63 Min Switch Frequency
Set the minimum switching frequency allowed by the output
filter.
Option:
[2]
*
[3]
[4]
[5]
4
4
[6]
[7]
[8]
[9]
[10]
14-64 Dead Time Compensation Zero Current Level
For a long motor cable, set this parameter to [0] Disabled to
minimize the motor-torque ripple.
Option:
[0]
*
[1]
14-65 Speed Derate Dead Time Compensation
Range:
Size
related
1000 Hz]
*
4.11.8 14-8* Options
14-89 Option Detection
Selects the behavior when an option change is detected. This
parameter returns to [0] Protect Option Config. after an option
change.
Option:
[0]
Protect Option Config. Freezes the current settings and
*
[1]
Enable Option
Change
92
Function:
2.0 kHz
3.0 kHz
4.0 kHz
5.0 kHz
6.0 kHz
8.0 kHz
10.0 kHz
12.0 kHz
16.0 kHz
Function:
Disabled
Enabled
Function:
[ 20 -
Deadtime compensation level is reduced
linearly in relation to output frequency.
Parameter 14-07 Dead Time Compensation
Level sets the maximum level. The
minimum output frequency level is
defined in parameter 14-65 Speed Derate
Dead Time Compensation.
Function:
prevents unwanted changes when
missing or defective options are
detected.
Settings can be changed when the
system configuration is being
modified.
Danfoss A/S © 11/2015 All rights reserved.
®
VLT
DriveMotor FCP 106/FCM 106
4.11.9 14-9* Fault Settings
Fault customization settings
14-90 Fault Level
Use this parameter to customize fault levels. Setting the
parameter value may change parameter 1–73 Flying Start.
Option:
[3]
*
[4]
[5]
Function:
Trip lock
Trip with delayed reset
Flystart
MG03N202