Parameters
15-42 Voltage
Range:
0
[0 - 20 ] View the FC type code.The readout is identical to
*
15-43 Software Version
Range:
4
4
0
[0 - 0 ] View the software version of the frequency
*
15-44 Ordered TypeCode
Range:
0
[0 - 40 ] View the type code string used for reordering the
*
15-45 Actual Typecode String
Range:
0
[0 - 40 ]
*
15-46 Drive Ordering No
Range:
0
[0 - 8 ] View the 8-digit ordering number used for
*
15-48 LCP Id No
Range:
0
[0 - 0 ]
*
15-49 SW ID Control Card
Range:
0
[0 - 0 ]
*
15-50 SW ID Power Card
Range:
0
[0 - 0 ]
*
15-51 Drive Serial Number
Range:
0
[0 - 10 ]
*
15-52 OEM Information
Range:
0
[0 - 0 ] View the OEM Information. The information is set
*
94
Function:
the frequency converter series power field of the
type code definition, characters 11–12.
Function:
converter.
Function:
frequency converter in its original configuration.
Function:
View the actual type code string.
Function:
reordering the frequency converter in its original
configuration.
Function:
View the LCP ID number.
Function:
View the control card software version number.
Function:
View the power card software version number.
Function:
View the frequency converter serial number.
Function:
in set-up software MCT 21.
[0] OEM Name
[1] OEM Type Code
[2] OEM Identification number
[3] OEM Serial Number
Danfoss A/S © 11/2015 All rights reserved.
®
VLT
DriveMotor FCP 106/FCM 106
15-53 Power Card Serial Number
Range:
0
[0 - 0 ]
*
15-57 File Version
Range:
0
[0 - 255 ] View file version. The file version is set in set-up
*
15-59 Filename
Range:
0
*
4.12.4 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0, and C1.
15-60 Option Mounted
Array [8]
Range:
Size related
15-61 Option SW Version
Array [8]
Range:
Size related
15-62 Option Ordering No
Range:
Size related
15-63 Option Serial No
Range:
Size related
15-70 Option in Slot A
Range:
0
[0 - 30 ] View the type code string for the option installed
*
15-71 Slot A Option SW Version
Range:
0
[0 - 20 ] View the software version for the option installed
*
Function:
View the power card serial number.
Function:
software MCT21.
[0] OEM-SIVP File Version
[1] Motor Database File Version
[2] Pump Table File Version
Function:
[0 - 16 ]
CSIV Filename readout.
Function:
[0 - 30 ]
View the installed option type.
*
Function:
[0 - 20 ] View the installed option software
*
version.
Function:
[0 - 8 ] Shows the ordering number for the
*
installed options.
Function:
[0 - 18 ] View the installed option serial number.
*
Function:
in slot A, and a translation of the type code string.
For example, for type code string AX, the
translation is No option.
Function:
in slot A.
MG03N202