Parameters
1-11 Motor Selection
Option:
[1]
Motor Selection 1
[2]
Motor Selection 2
4
4
[3]
Motor Selection 3
[4]
Motor Selection 4
[5]
Motor Selection 5
[6]
Motor Selection 6
[7]
Motor Selection 7
[8]
Motor Selection 8
[9]
Motor Selection 9
[10] Motor Selection 10
[11] Motor Selection 11
[12] Motor Selection 12
[13] Motor Selection 13
[14] Motor Selection 14
[15] Motor Selection 15
[16] Motor Selection 16
[17] Motor Selection 17
[18] Motor Selection 18
[19] Motor Selection 19
[20] Motor Selection 20
[21] Motor Selection 21
[22] Motor Selection 22
[23] Motor Selection 23
[24] Motor Selection 24
[25] Motor Selection 25
[26] Motor Selection 26
[27] Motor Selection 27
[28] Motor Selection 28
[29] Motor Selection 29
[30] Motor Selection 30
[31] Motor Selection 31
[32] Motor Selection 32
[33] Motor Selection 33
[34] Motor Selection 34
[35] Motor Selection 35
[36] Motor Selection 36
[37] Motor Selection 37
[38] Motor Selection 38
[39] Motor Selection 39
[40] Motor Selection 40
[41] Motor Selection 41
[42] Motor Selection 42
[43] Motor Selection 43
[44] Motor Selection 44
[45] Motor Selection 45
[46] Motor Selection 46
[47] Motor Selection 47
[48] Motor Selection 48
42
®
VLT
DriveMotor FCP 106/FCM 106
Function:
Setting the parameter value might
change these parameters. Other
parameters also change, when
changing motor type selection.
Danfoss A/S © 11/2015 All rights reserved.
1-11 Motor Selection
Option:
[49] Motor Selection 49
[50] Motor Selection 50
[51] Motor Selection 51
[52] Motor Selection 52
[53] Motor Selection 53
[54] Motor Selection 54
[55] Motor Selection 55
[56] Motor Selection 56
[57] Motor Selection 57
[58] Motor Selection 58
[59] Motor Selection 59
[60] Motor Selection 60
[61] Motor Selection 61
[62] Motor Selection 62
[63] Motor Selection 63
[64] Motor Selection 64
1-12 Motor ID
Range:
Function:
Default
[0 - 0 ] Shows motor name according to the
Motor
selected motor in parameter 1-11 Motor
*
Selection.
4.2.3 1-14 to 1-17 VVC
The default control parameters for VVC
core are optimized for HVAC applications and inertia load
in the range of 50>Jl/Jm>5. Jl is load inertia from the
application and Jm is machine inertia.
For low inertia applications (Jl/Jm<5), it is recommended
that parameter 1-17 Voltage filter time const. is increased
with a factor of 5–10. Sometimes,
parameter 14-08 Damping Gain Factor should also be
reduced to improve performance and stability.
For high inertia applications (Jl/Jm>50), it is recommended
that parameter 1-15 Low Speed Filter Time Const.,
parameter 1-16 High Speed Filter Time Const., and
parameter 14-08 Damping Gain Factor are increased to
improve performance and stability.
For high load at low speed (<30% of rated speed), it is
recommended that parameter 1-17 Voltage filter time const.
is increased due to non-linearity in the inverter at low
speed.
1-14 Damping Gain
Range:
Function:
120
[0 -
The parameter stabilizes the PM motor to ensure
%
250 %]
smooth and stable operation. The value of
*
damping gain controls the dynamic performance
of the PM motor. Low damping gain results in
high dynamic performance and a high value
results in a low dynamic performance. The
dynamic performance is related to the motor data
Function:
+
PM
+
PM motor control
MG03N202