Main Menu - Special Features - Group - Danfoss VLT DriveMotor FCP 106 Programming Manual

Hide thumbs Also See for VLT DriveMotor FCP 106:
Table of Contents

Advertisement

Parameters

4.18 Main Menu - Special Features - Group

30
4.18.1 30-2* Adv. Start Adjust
30-20 High Starting Torque Time [s]
Range:
Size related
*
4
4
30-21 High Starting Torque Current [%]
Range:
Size related
*
30-22 Locked Rotor Detection
Locked Rotor Detection for PM motor.
Option:
[0]
[1]
*
30-23 Locked Rotor Detection Time [s]
Range:
1 s
[0.05 - 1 s]
*
116
Function:
[0 - 60 s] High starting torque time for PM
+
motors in VVC
mode without
feedback.
Function:
[ 0 - 200.0 %] High starting torque current for PM
+
motor in VVC
mode without
feedback.
Function:
Off
On
Function:
Locked Rotor Detection Time for PM motor.
Danfoss A/S © 11/2015 All rights reserved.
®
VLT
DriveMotor FCP 106/FCM 106