Parameters
parameter 13-44 Logic Rule Boolean 3. Define the operators
used to combine the selected inputs logically in
parameter 13-41 Logic Rule Operator 1, and
parameter 13-43 Logic Rule Operator 2.
Par. 13-41
Logic Rule Operator 1
Par. 13-40
Logic Rule Boolean 1
Par. 13-42
Logic Rule Boolean 2
. . .
. . .
Par. 13-44
Logic Rule Boolean 3
Illustration 4.18 Logic Rules
Priority of calculation
The results of parameter 13-40 Logic Rule Boolean 1,
parameter 13-41 Logic Rule Operator 1, and
parameter 13-42 Logic Rule Boolean 2 are calculated first.
The outcome (true/false) of this calculation is combined
with the settings of parameter 13-43 Logic Rule Operator 2
and parameter 13-44 Logic Rule Boolean 3, yielding the final
result (true/false) of the logic rule.
13-40 Logic Rule Boolean 1
Array [6]
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
MG03N202
Programming Guide
13-40 Logic Rule Boolean 1
Array [6]
Option:
[36]
[39]
Par. 13-43
[40]
Logic Rule Operator 2
[42]
[50]
[51]
. . .
[60]
. . .
[61]
[70]
[71]
[72]
[73]
[74]
[81]
[82]
[83]
13-41 Logic Rule Operator 1
Option:
[0]
*
[1]
[2]
[3]
Function:
[4]
[5]
[6]
[7]
[8]
13-42 Logic Rule Boolean 2
Array [6]
Option:
[0]
*
[1]
[2]
[3]
[4]
[7]
[8]
[9]
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
Danfoss A/S © 11/2015 All rights reserved.
Digital input DI29
Start command
Drive stopped
Auto Reset Trip
Comparator 4
Comparator 5
Logic rule 4
Logic rule 5
SL Time-out 3
SL Time-out 4
SL Time-out 5
SL Time-out 6
SL Time-out 7
Dry Pump
End of Curve
Broken Belt
Disabled
AND
OR
AND NOT
OR NOT
NOT AND
NOT OR
NOT AND NOT
NOT OR NOT
Function:
Select the 2nd boolean (true or false)
input for the selected logic rule.
See parameter 13-40 Logic Rule
Boolean 1 for further descriptions of
options and their functions.
False
True
Running
In range
On reference
Out of current range
Below I low
Above I high
Function:
4
Function:
85
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt drivemotor fcm 106

Table of Contents