Parameter Lists

6.1.11 13-** Smart Logic

Par.
Parameter description
No. #
13-0* SLC Settings
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-1* Comparators
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-2* Timers
13-20
SL Controller Timer
13-4* Logic Rules
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-5* States
13-51
SL Controller Event
13-52
SL Controller Action

6.1.12 14-** Special Functions

Par.
Parameter description
No. #
14-0* Inverter Switching
14-01
Switching Frequency
14-03
Overmodulation
14-07
Dead Time Compensation Level
14-08
Damping Gain Factor
14-09
Dead Time Bias Current Level
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-2* Reset Functions
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-27
Action At Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
14-31
Current Lim Ctrl, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimising
14-40
VT Level
MG03N202
Programming Guide
Default value
[0] Off
[39] Start command
[40] Drive stopped
[0] Do not reset SLC
[0] Disabled
[1] Approx.Equal (~)
0 N/A
0 s
[0] False
[0] Disabled
[0] False
[0] Disabled
[0] False
[0] False
[0] Disabled
Default value
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] No function
ExpressionLimit
[0] Trip
[0] Manual reset
10 s
[0] Normal operation
[1] Warning
[0] No action
0 N/A
100%
ExpressionLimit
ExpressionLimit
90%
Danfoss A/S © 11/2015 All rights reserved.
4-set-up
Change
during
operation
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
4-set-up
Change
Conversion
during
operation
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
Conversion
Type
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Int32
6
-2
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Type
index
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint16
-3
Uint16
-4
Uint16
0
Uint8
135
6