Parameters
Digital input
function
[64] Counter B
(down)
[65] Reset Counter B Input for reset of counter B
Table 4.4 Digital Input Functions
4
4
Selected
preset
reference:
Preset
reference 0
Preset
reference 1
Preset
reference 2
Preset
reference 3
Preset
reference 4
Preset
reference 5
Preset
reference 6
Preset
reference 7
Table 4.5 Selected Preset Reference
5-10 Terminal 18 Digital Input
Parameter for configuring the input function on input terminal
18. Refer to Table 4.4 for setting options.
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
*
[9]
[10]
[11]
[14]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
60
VLT
Description
Input for decrement counting in the SLC
counter.
Preset
Preset
reference bit 2
reference bit 1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC-brake inverse
Stop inverse
External Interlock
Start
Latched start
Reversing
Start reversing
Jog
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Danfoss A/S © 11/2015 All rights reserved.
®
DriveMotor FCP 106/FCM 106
5-10 Terminal 18 Digital Input
Parameter for configuring the input function on input terminal
18. Refer to Table 4.4 for setting options.
Option:
[23]
[34]
[37]
[52]
[53]
Preset
[54]
reference bit 0
[60]
[61]
0
[62]
[63]
1
[64]
[65]
0
[101]
1
5-11 Terminal 19 Digital Input
Parameter for configuring the input function on input terminal
0
19.
Option:
1
[0]
*
0
[1]
[2]
1
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
Function:
[11]
[14]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[34]
[37]
[52]
[53]
[54]
[60]
[61]
[62]
[63]
[64]
[65]
Set-up select bit 0
Ramp bit 0
Fire Mode
Run permissive
Hand start
Auto start
Counter A (up)
Counter A (down)
Reset Counter A
Counter B (up)
Counter B (down)
Reset Counter B
Sleep
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC-brake inverse
Stop inverse
External Interlock
Start
Latched start
Reversing
Start reversing
Jog
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Set-up select bit 0
Ramp bit 0
Fire Mode
Run permissive
Hand start
Auto start
Counter A (up)
Counter A (down)
Reset Counter A
Counter B (up)
Counter B (down)
Reset Counter B
Function:
Function:
MG03N202