Appl. Functions - Danfoss VLT DriveMotor FCP 106 Programming Manual

Hide thumbs Also See for VLT DriveMotor FCP 106:
Table of Contents

Advertisement

Parameter Lists
Par.
Parameter description
No. #
20-84
On Reference Bandwidth
20-9* PI Controller
20-91
PI Anti Windup
20-93
PI Proportional Gain
20-94
PI Integral Time
20-97
PI Feed Forward Factor

6.1.17 22-** Appl. Functions

Par.
Parameter description
No. #
22-0* Miscellaneous
22-01
Power Filter Time
22-02
Sleepmode CL Control Mode
22-2* No-Flow Detection
22-26
Dry Pump Function
22-27
Dry Pump Delay
22-3* No-Flow Power Tuning
22-38
High Speed Power [kW]
22-4* Sleep Mode
22-40
Minimum Run Time
22-41
Minimum Sleep Time
22-43
Wake-Up Speed [Hz]
22-44
Wake-Up Ref./FB Diff
22-45
Setpoint Boost
22-46
Maximum Boost Time
22-47
Sleep Speed [Hz]
22-48
Sleep Delay Time
22-49
Wake-Up Delay Time
22-5* End of Curve
22-50
End of Curve Function
22-51
End of Curve Delay
22-6* Broken Belt Detection
22-60
Broken Belt Function
22-61
Broken Belt Torque
22-62
Broken Belt Delay
22-8* Flow Compensation
22-80
Flow Compensation
22-81
Square-linear Curve Approximation
22-82
Work Point Calculation
22-84
Speed at No-Flow [Hz]
22-86
Speed at Design Point [Hz]
22-87
Pressure at No-Flow Speed
22-88
Pressure at Rated Speed
22-89
Flow at Design Point
22-90
Flow at Rated Speed
MG03N202
Programming Guide
Default value
5%
[1] On
0.50 N/A
20 s
0%
Default value
0.50 s
[0] Normal
[0] Off
10 s
ExpressionLimit
10 s
10 s
10 N/A
10%
0%
60 s
0 N/A
0 s
0 s
[0] Off
10 s
[0] Off
10%
10 s
[0] Disabled
100%
[0] Disabled
0 Hz
ExpressionLimit
0 N/A
999999.999 N/A
0 N/A
0 N/A
Danfoss A/S © 11/2015 All rights reserved.
4-set-up
Change
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
Change
during
operation
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conversion
Type
index
0
Uint8
-
Uint8
-2
Uint16
-2
Uint32
0
Uint16
Conversion
Type
index
6
-2
Uint16
-
Uint8
-
Uint8
0
Uint16
1
Uint32
0
Uint16
0
Uint16
-1
Uint16
0
Uint8
0
Int8
0
Uint16
-1
Uint16
0
Uint16
0
Uint16
-
Uint8
0
Uint16
-
Uint8
0
Uint8
0
Uint16
-
Uint8
0
Uint8
-
Uint8
-1
Uint16
-1
Uint16
-3
Uint32
-3
Uint32
-3
Int32
-3
Int32
139