Danfoss VLT AutomationDrive FC 301 Programming Manual page 85

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
5-32 Term X30/6 Digi Out (MCB 101)
Option:
[0]
No operation
[1]
Control Ready
[2]
Drive ready
[3]
Drive rdy/rem ctrl
[4]
Enable / no warning
[5]
Running
[6]
Running / no warning
[7]
Run in range/no warn
[8]
Run on ref/no warn
[9]
Alarm
[10]
Alarm or warning
[11]
At torque limit
[12]
Out of current range
[13]
Below current, low
[14]
Above current, high
[15]
Out of speed range
[16]
Below speed, low
[17]
Above speed, high
[18]
Out of feedb. range
[19]
Below feedback, low
[20]
Above feedback, high
[21]
Thermal warning
[22]
Ready,no thermal W
[23]
Remote,ready,no TW
[24]
Ready, Voltage OK
[25]
Reverse
[26]
Bus OK
[27]
Torque limit & stop
[28]
Brake, no brake war
[29]
Brake ready, no fault
[30]
Brake fault (IGBT)
[31]
Relay 123
[32]
Mech brake ctrl
[33]
Safe stop active
[38]
Motor feedback error
[39]
Tracking error
[40]
Out of ref range
[41]
Below reference, low
[42]
Above ref, high
[43]
Extended PID Limit
[45]
Bus ctrl.
[46]
Bus ctrl, 1 if timeout
[47]
Bus ctrl, 0 if timeout
[51]
MCO controlled
[55]
Pulse output
[60]
Comparator 0
[61]
Comparator 1
®
VLT
AutomationDrive FC 301/302 Programming Guide
Function:
This parameter is active when
option module MCB 101 is
mounted in the frequency
converter. Functions are described
under parameter group 5-3*
Digital Outputs
MG33MH02 - Rev. 2013-09-30
5-32 Term X30/6 Digi Out (MCB 101)
Option:
Function:
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic rule 0
[71]
Logic rule 1
[72]
Logic rule 2
[73]
Logic rule 3
[74]
Logic rule 4
[75]
Logic rule 5
[80]
SL digital output A
[81]
SL digital output B
[82]
SL digital output C
[83]
SL digital output D
[84]
SL digital output E
[85]
SL digital output F
[120] Local ref active
[121] Remote ref active
[122] No alarm
[123] Start command activ
[124] Running reverse
[125] Drive in hand mode
[126] Drive in auto mode
[151] ATEX ETR cur. alarm
[152] ATEX ETR freq. alarm
[153] ATEX ETR cur. warning
[154] ATEX ETR freq. warning
[188] AHF Capacitor Connect
[189] External Fan Control
[190] Safe Function active
[191] Safe Opt. Reset req.
[192] RS Flipflop 0
[193] RS Flipflop 1
[194] RS Flipflop 2
[195] RS Flipflop 3
[196] RS Flipflop 4
[197] RS Flipflop 5
[198] RS Flipflop 6
[199] RS Flipflop 7
5-33 Term X30/7 Digi Out (MCB 101)
Option:
Function:
[0]
No operation
This parameter is active when
option module option module
MCB 101 is mounted in the
frequency converter. Functions are
described under parameter group
5-3* Digital Outputs
[1]
Control Ready
[2]
Drive ready
[3]
Drive rdy/rem ctrl
[4]
Enable / no warning
3
3
83