Parameter Lists
4.1.15 12-** Ethernet
Par. No. # Parameter description
12-0* IP Settings
12-00
IP Address Assignment
12-01
IP Address
4
4
12-02
Subnet Mask
12-03
Default Gateway
12-04
DHCP Server
12-05
Lease Expires
12-06
Name Servers
12-07
Domain Name
12-08
Host Name
12-09
Physical Address
12-1* Ethernet Link Parameters
12-10
Link Status
12-11
Link Duration
12-12
Auto Negotiation
12-13
Link Speed
12-14
Link Duplex
12-2* Process Data
12-20
Control Instance
12-21
Process Data Config Write
12-22
Process Data Config Read
12-23
Process Data Config Write Size
12-24
Process Data Config Read Size
12-27
Master Address
12-28
Store Data Values
12-29
Store Always
12-3* EtherNet/IP
12-30
Warning Parameter
12-31
Net Reference
12-32
Net Control
12-33
CIP Revision
12-34
CIP Product Code
12-35
EDS Parameter
12-37
COS Inhibit Timer
12-38
COS Filter
12-4* Modbus TCP
12-40
Status Parameter
12-41
Slave Message Count
12-42
Slave Exception Message Count
12-5* EtherCAT
12-50
Configured Station Alias
12-51
Configured Station Address
12-59
EtherCAT Status
12-6* Ethernet PowerLink
12-60
Node ID
12-62
SDO Timeout
12-63
Basic Ethernet Timeout
12-66
Threshold
12-67
Threshold Counters
182
®
VLT
AutomationDrive FC 301/302 Programming Guide
Default value
4-set-up
ExpressionLimit
2 set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
2 set-ups
ExpressionLimit
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[0] No Link
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
1 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
16 N/A
All set-ups
16 N/A
All set-ups
0 N/A
2 set-ups
[0] Off
All set-ups
[0] Off
1 set-up
0 N/A
All set-ups
[0] Off
2 set-ups
[0] Off
2 set-ups
ExpressionLimit
All set-ups
ExpressionLimit
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
1 N/A
2 set-ups
30000 ms
All set-ups
5000.000 ms
All set-ups
15 N/A
All set-ups
0 N/A
All set-ups
MG33MH02 - Rev. 2013-09-30
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
FALSE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
FALSE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-3
TRUE
-6
TRUE
0
TRUE
0
Type
Uint8
OctStr[4]
OctStr[4]
OctStr[4]
OctStr[4]
TimD
OctStr[4]
VisStr[48]
VisStr[48]
VisStr[17]
Uint8
TimD
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint32
Uint32
OctStr[4]
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint32
Uint16
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint32
Uint8
Uint32
Uint32
Uint32
Uint32