Parameter Lists
Par. No. # Parameter description
Process PID Gain Scale at Min.
7-43
Ref.
Process PID Gain Scale at Max.
7-44
Ref.
7-45
Process PID Feed Fwd Resource
Process PID Feed Fwd Normal/
7-46
Inv. Ctrl.
7-48
PCD Feed Forward
Process PID Output Normal/ Inv.
7-49
Ctrl.
7-5* Adv. Process PID II
7-50
Process PID Extended PID
7-51
Process PID Feed Fwd Gain
7-52
Process PID Feed Fwd Ramp up
Process PID Feed Fwd Ramp
7-53
down
7-56
Process PID Ref. Filter Time
7-57
Process PID Fb. Filter Time
4.1.12 8-** Comm. and Options
Par. No. # Parameter description
8-0* General Settings
8-01
Control Site
8-02
Control Word Source
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Word Timeout
8-07
Diagnosis Trigger
8-08
Readout Filtering
8-1* Ctrl. Word Settings
8-10
Control Word Profile
8-13
Configurable Status Word STW
8-14
Configurable Control Word CTW
8-19
Product Code
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-33
Parity / Stop Bits
8-34
Estimated cycle time
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram Selection
8-41
Parameters for Signals
®
VLT
AutomationDrive FC 301/302 Programming Guide
Default value
4-set-up
100 %
All set-ups
100 %
All set-ups
[0] No function
All set-ups
[0] Normal
All set-ups
0 N/A
All set-ups
[0] Normal
All set-ups
[1] Enabled
All set-ups
1 N/A
All set-ups
0.01 s
All set-ups
0.01 s
All set-ups
0.001 s
All set-ups
0.001 s
All set-ups
Default value
4-set-up
[0] Digital and ctrl.word
All set-ups
ExpressionLimit
All set-ups
1 s
1 set-up
ExpressionLimit
1 set-up
[1] Resume set-up
1 set-up
[0] Do not reset
All set-ups
[0] Disable
2 set-ups
ExpressionLimit
All set-ups
[0] FC profile
All set-ups
ExpressionLimit
All set-ups
[1] Profile default
All set-ups
ExpressionLimit
1 set-up
[0] FC
1 set-up
1 N/A
1 set-up
ExpressionLimit
1 set-up
[0] Even Parity, 1 Stop
Bit
1 set-up
0 ms
2 set-ups
10 ms
1 set-up
ExpressionLimit
1 set-up
ExpressionLimit
1 set-up
[1] Standard telegram 1
2 set-ups
0
All set-ups
MG33MH02 - Rev. 2013-09-30
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
TRUE
0
TRUE
-
TRUE
-
x
TRUE
0
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-5
TRUE
-
FALSE
-
Type
Int16
Int16
Uint8
4
4
Uint8
Uint16
Uint8
Uint8
Uint16
Uint32
Uint32
Uint16
Uint16
Type
Uint8
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint32
Uint16
Uint16
Uint16
Uint8
Uint16
179