Parameter Lists
Par. No. # Parameter description
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
4
4
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-54
Pulse Filter Time Constant #29
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-59
Pulse Filter Time Constant #33
5-6* Pulse Output
Terminal 27 Pulse Output
5-60
Variable
5-62
Pulse Output Max Freq #27
Terminal 29 Pulse Output
5-63
Variable
5-65
Pulse Output Max Freq #29
Terminal X30/6 Pulse Output
5-66
Variable
5-68
Pulse Output Max Freq #X30/6
5-7* 24V Encoder Input
5-70
Term 32/33 Pulses Per Revolution
5-71
Term 32/33 Encoder Direction
5-8* I/O Options
5-80
AHF Cap Reconnect Delay
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
5-93
Pulse Out #27 Bus Control
5-94
Pulse Out #27 Timeout Preset
5-95
Pulse Out #29 Bus Control
5-96
Pulse Out #29 Timeout Preset
5-97
Pulse Out #X30/6 Bus Control
5-98
Pulse Out #X30/6 Timeout Preset
4.1.10 6-** Analog In/Out
Par. No. # Parameter description
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-1* Analog Input 1
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
176
®
VLT
AutomationDrive FC 301/302 Programming Guide
Default value
4-set-up
0.01 s
All set-ups
0.01 s
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
1024 N/A
All set-ups
[0] Clockwise
All set-ups
25 s
2 set-ups
0 N/A
All set-ups
0 %
All set-ups
0 %
1 set-up
0 %
All set-ups
0 %
1 set-up
0 %
All set-ups
0 %
1 set-up
Default value
4-set-up
10 s
All set-ups
[0] Off
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0.14 mA
All set-ups
MG33MH02 - Rev. 2013-09-30
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-2
TRUE
-2
x
TRUE
0
x
TRUE
0
x
TRUE
-3
x
TRUE
-3
x
FALSE
-3
TRUE
0
TRUE
0
TRUE
-3
TRUE
-3
FALSE
-3
TRUE
-
TRUE
0
x
TRUE
-
x
TRUE
0
TRUE
-
TRUE
0
FALSE
0
FALSE
-
x
TRUE
0
TRUE
0
TRUE
-2
TRUE
-2
x
TRUE
-2
x
TRUE
-2
TRUE
-2
TRUE
-2
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-5
Type
Uint16
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint8
Uint32
Uint8
Uint32
Uint8
Uint32
Uint16
Uint8
Uint16
Uint32
N2
Uint16
N2
Uint16
N2
Uint16
Type
Uint8
Uint8
Int16
Int16
Int16