Parameter Descriptions
30-81 Brake Resistor (ohm)
Range:
Function:
parameter is only active in frequency
converters with an integral dynamic
brake.
30-83 Speed PID Proportional Gain
Range:
Function:
Size related
[0 -
Enter the speed controller proportional
*
1 ]
gain. Quick control is obtained at high
amplification. However if amplification is
too great, the process may become
unstable.
30-84 Process PID Proportional Gain
Range:
Function:
0.100
[0 -
Enter the process controller proportional gain.
*
10 ]
Quick control is obtained at high amplification.
However if amplification is too great, the
process may become unstable.
®
VLT
AutomationDrive FC 301/302 Programming Guide
MG33MH02 - Rev. 2013-09-30
3
3
157