Parameter Descriptions
15-71 Slot A Option SW Version
Range:
Function:
0
[0 - 0 ] View the software version for the option installed
*
in slot A.
15-72 Option in Slot B
Range:
Function:
0
[0 - 0 ] View the type code string for the option installed
*
in slot B, and a translation of the type code string.
E.g. for type code string 'BX' the translation is 'No
option'.
15-73 Slot B Option SW Version
Range:
Function:
0
[0 - 0 ] View the software version for the option installed
*
in slot B.
15-74 Option in Slot C0/E0
Range:
Function:
0
[0 - 0 ] View the type code string for the option installed
*
in slot C, and a translation of the type code string.
E.g. for type code string 'CXXXX' the translation is
'No option'.
15-75 Slot C0/E0 Option SW Version
Range:
Function:
0
[0 - 0 ] View the software version for the option installed
*
in slot C.
15-76 Option in Slot C1/E1
Range:
Function:
0
[0 - 0 ] Displays the type code string for the option in slot
*
C1. (CXXXX if no option) and the translation i.e.
>No option<.
15-77 Slot C1/E1 Option SW Version
Range:
Function:
0
[0 - 0 ] Displays the software version for the installed
*
option in option slot C.
15-80 Fan Running Hours
Range:
Function:
0 h
[0 - 2147483647
View how many hours the heatsink fan
*
h]
has run (increments for each hour). The
value is saved when the frequency
converter is turned off.
15-81 Preset Fan Running Hours
Range:
Function:
0 h
[0 - 99999
Enter value to preset the Fan Running Hours
*
h]
counter, see 15-80 Fan Running Hours.
This parameter cannot be selected via the
serial port, RS-485.
®
VLT
AutomationDrive FC 301/302 Programming Guide
15-89 Configuration Change Counter
Range:
0
[0 - 65535 ]
*
3.16.7 15-9* Parameter Info
15-92 Defined Parameters
Array [1000]
Range:
0
[0 - 9999 ] View a list of all defined parameters in the
*
15-93 Modified Parameters
Array [1000]
Range:
0
[0 -
*
9999 ]
15-98 Drive Identification
Range:
0
[0 - 0 ] This parameter contains data that is used by the
*
15-99 Parameter Metadata
Array [30]
Range:
0
[0 - 9999 ] This parameter contains data used by the MCT
*
MG33MH02 - Rev. 2013-09-30
Function:
NOTICE
This parameter cannot be adjusted
while the motor is running.
Function:
frequency converter. The list ends with 0.
Function:
View a list of the parameters that have been
changed from their default setting. The list ends
with 0. Changes may not be visible until up to
30 s after implementation.
Function:
MCT10 software tool.
Function:
10 Set-up Software.
3
3
145
Need help?
Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?
Questions and answers