Danfoss VLT AutomationDrive FC 301 Programming Manual page 158

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
30-04 Wobble Jump Frequency [Hz]
Range:
3
3
30-05 Wobble Jump Frequency [%]
Range:
0 %
[0 - 100
*
%]
30-06 Wobble Jump Time
Range:
Size related
*
30-07 Wobble Sequence Time
Range:
10 s
[1 - 1000
*
s]
30-08 Wobble Up/ Down Time
Range:
5 s
[0.1 - 1000 s] Defines the individual up- and down times
*
30-09 Wobble Random Function
Option:
[0]
*
[1]
30-10 Wobble Ratio
Range:
1
[0.1 -
*
10 ]
30-11 Wobble Random Ratio Max.
Range:
10
[ par. 17-53 - 10 ] Enter the maximum allowed wobble
*
30-12 Wobble Random Ratio Min.
Range:
0.1
[ 0.1 - par. 30-11 ] Enter the minimum allowed wobble
*
156
Function:
system has a very high inertia a high jump
frequency may create a torque limit warning or
trip (warning/alarm 12) or an overvoltage warning
or trip (warning/alarm 7). This parameter can only
be changed in stop-mode
Function:
The jump frequency can also be expressed as
percentage of the center frequency. The
function is the same as for 30-04 Wobble Jump
Frequency [Hz].
[ 0.005 - 5.000 s]
Function:
This parameter determines the wobble
sequence period. This parameter can only be
changed in stop-mode.
Wobble time = t
+ t
up
down
Function:
for each wobble cycle.
Function:
Off
On
Function:
If the ratio 0.1 is selected: t
is 10 times greater
down
than t
.
up
If the ratio 10 is selected: t
is 10 times greater
up
than t
.
down
Function:
ratio.
Function:
ratio.
®
VLT
AutomationDrive FC 301/302 Programming Guide
30-19 Wobble Delta Freq. Scaled
Range:
0 Hz
*
3.20.2 30-2* Adv. Start Adjust
30-20 High Starting Torque Time [s]
Range:
Size related
30-21 High Starting Torque Current [%]
Function:
Range:
Size related
30-22 Locked Rotor Protection
Locked Rotor Protection for PM-Motor in Flux mode without
feedback. This parameter is available for FC 302 only.
Option:
[0]
[1]
30-23 Locked Rotor Detection Time [s]
This parameter is available for FC 302 only.
Range:
Size related
3.20.3 30-8* Compatibility
30-80 d-axis Inductance (Ld)
Range:
Size related
30-81 Brake Resistor (ohm)
Range:
Size
related
*
MG33MH02 - Rev. 2013-09-30
Function:
[0 - 1000 Hz] Readout parameter. View the actual
wobble delta frequency after scaling has
been applied.
Function:
[0 - 60
High starting torque time for PM-Motor
*
s]
in Flux mode without feedback. This
parameter is available for FC 302 only.
Function:
[ 0 - 200.0
High starting torque current for PM-
*
%]
Motor in and Flux mode without
feedback. This parameter is available
for FC 302 only.
Off
On
Function:
[0.05 - 1 s] Locked Rotor Detection Time for PM-
*
Motor in Flux mode without feedback.
Function:
[0.000 -
Enter the value of the d-axis
*
1000.000
inductance. Obtain the value from
mH]
the permanent magnet motor data
sheet. The d-axis inductance cannot
be found by performing an AMA.
Function:
Set the brake resistor value in Ω. This
[ 0.01 -
65535.00
value is used for monitoring the
Ohm]
power to the brake resistor in
2-13 Brake Power Monitoring. This
Function:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents