Parameter Descriptions
0-50 LCP Copy
Option:
Function:
[7]
Data from LCP to
DYN
[9]
Safety Par. from
LCP
0-51 Set-up Copy
Option:
Function:
[0] No copy
No function
[1] Copy to set-
Copies all parameters in the present
up 1
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 1.
[2] Copy to set-
Copies all parameters in the present
up 2
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 2.
[3] Copy to set-
Copies all parameters in the present
up 3
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 3.
[4] Copy to set-
Copies all parameters in the present
up 4
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 4.
[9] Copy to all
Copies the parameters in the present set-up
over to each of the set-ups 1 to 4.
3.2.7 0-6* Password
0-60 Main Menu Password
Range:
Function:
100
[-9999 -
Define the password for access to the Main
*
9999 ]
Menu via the [Main Menu] key. If 0-61 Access
to Main Menu w/o Password is set to [0] Full
access, this parameter will be ignored.
0-61 Access to Main Menu w/o Password
Option:
Function:
[0]
Full access
Disables password defined in 0-60 Main
*
Menu Password.
[1]
LCP: Read
Prevent unauthorised editing of Main Menu
only
parameters.
[2]
LCP: No
Prevent unauthorised viewing and editing
access
of Main Menu parameters.
[3]
Bus: Read only Read-only functions for parameters on
Fieldbus and/or FC standard bus.
[4]
Bus: No access No access to parameters is allowed via
Fieldbus and/or FC standard bus.
[5]
All: Read only
Read-only function for parameters on LCP,
Fieldbus or FC standard bus.
[6]
All: No access
No access from LCP, Fieldbus or FC
standard bus is allowed.
®
VLT
AutomationDrive FC 301/302 Programming Guide
If Full access [0] is selected then 0-60 Main Menu Password,
0-65 Personal Menu Password and 0-66 Access to Personal
Menu w/o Password is ignored.
NOTICE
A more complex Password protection is
available for OEMs upon request.
0-65 Quick Menu Password
Range:
200
[-9999 -
*
9999 ]
0-66 Access to Quick Menu w/o Password
Option:
[0]
Full access
*
[1]
LCP: Read
only
[3]
Bus: Read
only
[5]
All: Read only Read only function for Quick Menu
If 0-61 Access to Main Menu w/o Password is set to [0] Full
access then this parameter is ignored.
0-67 Bus Password Access
Range:
0
[0 - 9999 ] Writing to this parameter enables users to
*
MG33MH02 - Rev. 2013-09-30
Function:
Define the password for access to the Quick
Menu via the [Quick Menu] key. If 0-66 Access
to Quick Menu w/o Password is set to [0] Full
access, this parameter will be ignored.
Function:
Disables the password defined in 0-65 Quick
Menu Password.
Prevents unauthorised editing of Quick
Menu parameters.
Read only functions for Quick Menu
parameters on Fieldbus and/or FC standard
bus.
parameters on LCP, Fieldbus or FC standard
bus.
Function:
unlock the frequency converter from bus/MCT
10 Set-up Software.
3
3