Parameter Lists
Par. No. # Parameter description
8-42
PCD Write Configuration
8-43
PCD Read Configuration
8-45
BTM Transaction Command
8-46
BTM Transaction Status
8-47
BTM Timeout
4
4
8-48
BTM Maximum Errors
8-49
BTM Error Log
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Profidrive OFF2 Select
8-58
Profidrive OFF3 Select
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Messages Rcvd
8-83
Slave Error Count
8-9* Bus Jog
8-90
Bus Jog 1 Speed
8-91
Bus Jog 2 Speed
4.1.13 9-** Profibus
Par.
Parameter description
No. #
9-00
Setpoint
9-07
Actual Value
9-15
PCD Write Configuration
9-16
PCD Read Configuration
9-18
Node Address
9-19
Drive Unit System Number
9-22
Telegram Selection
9-23
Parameters for Signals
9-27
Parameter Edit
9-28
Process Control
9-44
Fault Message Counter
9-45
Fault Code
9-47
Fault Number
9-52
Fault Situation Counter
9-53
Profibus Warning Word
9-63
Actual Baud Rate
9-64
Device Identification
9-65
Profile Number
9-67
Control Word 1
180
®
VLT
AutomationDrive FC 301/302 Programming Guide
Default value
4-set-up
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] Off
All set-ups
[0] Off
All set-ups
60 s
1 set-up
21 N/A
1 set-up
0.255 N/A
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
ExpressionLimit
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
100 RPM
All set-ups
ExpressionLimit
All set-ups
Default value
4-set-up
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
1 set-up
ExpressionLimit
2 set-ups
126 N/A
1 set-up
1034 N/A
All set-ups
[100] None
1 set-up
0
All set-ups
[1] Enabled
2 set-ups
[1] Enable cyclic master
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[255] No baudrate found
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
MG33MH02 - Rev. 2013-09-30
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
TRUE
0
FALSE
-
TRUE
-
FALSE
0
TRUE
0
TRUE
-3
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
67
TRUE
67
FC 302
Change
Conver-
only
during
operation
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Type
Uint16
Uint16
Uint8
Uint8
Uint16
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
sion
index
0
Uint16
0
Uint16
-
Uint16
-
Uint16
0
Uint8
0
Uint16
-
Uint8
-
Uint16
-
Uint16
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
V2
-
Uint8
0
Uint16
OctStr[
0
2]
0
V2