Table 101: MX2010 Cooling System Alarms (continued)
Component
Temperature sensors
RELATED DOCUMENTATION
MX2010 Craft Interface Description | 29
Replacing an MX2010 Fan Tray | 508
Maintaining the MX2010 Air Filters | 609
Maintaining the MX2010 Fan Trays | 615
Alarm
Type
CLI Message
Red
Temperature Hot
Temperature sensor
failure
Yellow
Temperature Warm
Alarm Condition
Solution
The chassis
Verify that the
temperature
room temperature
exceeded the hot
is within
temperature
acceptable limits.
threshold. If this
Verify that there
condition persists, the
is sufficient air
router shuts down.
flow.
Verify that the
cooling system in
the chassis is
operating
properly.
A temperature sensor
Contact JTAC
failed.
The chassis
Verify that the
temperature
room temperature
exceeded the warm
is within
temperature
acceptable limits.
threshold.
Verify that there
is sufficient air
flow.
Verify that the
cooling system in
the chassis is
operating
properly.