Juniper MX2010 Hardware Manual page 418

Universal routing platform
Hide thumbs Also See for MX2010:
Table of Contents

Advertisement

If the OK/FAIL LED is red, remove and install the CB-RE again. If the OK/FAIL LED still lights steadily,
the CB-RE is not functioning properly. Contact your customer support representative. See
Customer Support" on page
7. Check the status of the CB-RE by using the show chassis environment cb command:
user@host> show chassis environment cb
CB 0 status:
State
IntakeA-Zone0 Temperature
IntakeB-Zone1 Temperature
IntakeC-Zone0 Temperature
ExhaustA-Zone0 Temperature 26 degrees C / 78 degrees F
ExhaustB-Zone1 Temperature 28 degrees C / 82 degrees F
TCBC-Zone0 Temperature
Power 1
1.0 V
1.2 V
1.8 V
2.5 V
3.3 V
5.0 V
5.0 V RE
12.0 V
12.0 V RE
Bus Revision
FPGA Revision
CB 1 status:
State
IntakeA-Zone0 Temperature
IntakeB-Zone1 Temperature
IntakeC-Zone0 Temperature
ExhaustA-Zone0 Temperature 33 degrees C / 91 degrees F
ExhaustB-Zone1 Temperature 28 degrees C / 82 degrees F
TCBC-Zone0 Temperature
Power 1
1.0 V
1.2 V
1.8 V
2.5 V
3.3 V
5.0 V
5.0 V RE
12.0 V
12.0 V RE
731.
Online Master
25 degrees C / 77 degrees F
29 degrees C / 84 degrees F
28 degrees C / 82 degrees F
32 degrees C / 89 degrees F
1008 mV
1208 mV
1801 mV
2526 mV
3312 mV
5020 mV
4995 mV
12123 mV
12007 mV
100
271
Online Standby
30 degrees C / 86 degrees F
25 degrees C / 77 degrees F
39 degrees C / 102 degrees F
31 degrees C / 87 degrees F
1015 mV
1211 mV
1814 mV
2545 mV
3345 mV
5066 mV
5020 mV
12104 mV
12046 mV
402
"Contacting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents