Juniper MX2010 Hardware Manual page 466

Universal routing platform
Hide thumbs Also See for MX2010:
Table of Contents

Advertisement

NOTE:
The air filter has a built-in handle.
4. Slide the air filter out of the chassis as shown in
Figure 214: Removing the Lower Air Filter from the Chassis
To remove the card-cage cable manager air filter—MX2000-CBL-MID:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. Move the cables from the card-cage cable manager, if necessary.
3. Loosen the two captive screws located on the front of the card-cage cable manager door.
CAUTION:
in place.
4. Open the cable manager door to get access to the air filter.
5. Grasp the air filter, and pull the air filter straight out from the access door (see
Figure 214 on page
D
Do not run the router for more than 2 minutes without the air filter
450.
Figure 215 on page
450
451).