Issue the show chassis power command to display the information about the AC or DC power system.
The following output displays the AC chassis power for 2500 W capacity.
user@hostshow chassis power
PSM 0:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)
Capacity:
2500 W (maximum 2500 W)
DC output: 349.31 W (6.75 A at 51.75 V, 13.97% of capacity)
PSM 1:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)
Capacity:
2500 W (maximum 2500 W)
DC output: 325.00 W (6.25 A at 52.00 V, 13.00% of capacity)
PSM 2:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)
Capacity:
2500 W (maximum 2500 W)
DC output: 375.19 W (7.25 A at 51.75 V, 15.01% of capacity)
PSM 3:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)
Capacity:
2500 W (maximum 2500 W)
DC output: 362.25 W (7.00 A at 51.75 V, 14.49% of capacity)
PSM 4:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)
Capacity:
2500 W (maximum 2500 W)
DC output: 364.00 W (7.00 A at 52.00 V, 14.56% of capacity)
PSM 5:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)
Capacity:
2500 W (maximum 2500 W)
DC output: 364.00 W (7.00 A at 52.00 V, 14.56% of capacity)
PSM 6:
State:
Online
AC input:
OK (Both feed expected, Both feed connected)