General Settings; Access Levels; Definition Of Access Levels; Modifying The Access Levels Password - Siemens SINUMERIK 828D Commissioning Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

General settings

1.1

Access levels

1.1.1

Definition of access levels

Access to programs, data and functions is protected in a user-oriented hierarchical system of
seven access levels. These are divided into
● Three password levels for manufacturer, service and users
● Four keyswitch positions for users
There are access levels 1 to 7 (see table below); where
● 1 is the highest and
● 7 is the lowest level.
Table 1-1
Access level
1
2
3
4
5
6
7
1.1.2

Modifying the access levels password

Overview
You can activate the access levels protected with passwords from the user interface.
The following options are available for editing the passwords:
● Set new password
● Change password
● Delete password
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Access level concept
Protected by
Password: SUNRISE (default value)
Password: EVENING (default value)
Password: CUSTOMER (default value)
Keyswitch 3
Keyswitch 2
Keyswitch 1
Keyswitch 0
Area
Manufacturer
Service
User
Programmer, machine setter
Qualified operator
Trained operator
Semi-skilled operator
1
9

Hide quick links: