5. The configuration data of the new module is read in.
6. Update the drive data in the commissioning archive with the new configuration data.
5.1.9

Example: Parallel connection with TM120

Topology
Application: Four motors connected in parallel
M1 ... M4
SMx
ALM
DMM
SMM
TM120
The shown topology requires four KTY sensors and four PTC sensors:
● Each primary section has one KTY sensor (Temp-F) and three series-connected PTC
sensors (Temp-S).
Two TM120s are required:
● A TM120 is interconnected automatically in series between the Motor Module and the SMx
Sensor Module.
● A TM120 is directly inserted into a Line Module: This requires a manual interconnection by
the commissioning engineer.
CNC commissioning
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Motor 1 ... motor 4
One KTY and three PTC in series are connected for each motor.
Sensor Module (motor encoder)
Active Line Module
Double Motor Module
Single Motor Module
Terminal Module
Commissioning the drive