<item value = "10" >text1</item>
<item value = "20" >text2</item>
<item value = "12" >text3</item>
<item value = "1" >text4</item>
</control>
Note
"hotlink" attribute
The hotlink attribute results in a cyclic update of the corresponding control. This means that
when a value is entered, the following update cycle overwrites the entered value. To avoid this
behavior, the immediate saving of the entries must be activated with the DATA_ACCESS tag.
Another possibility is to take the SOFTKEY_OK identifier into the form. This identifier is
performed before the dialog is closed. In this block, the data comparison can be made between
the control and reference variables with the UPDATE_CONTROLS statement.
8.6.3

Example of a power unit

Note
The two examples are also supplied on the SINUMERIK 828D Toolbox → Examples.
Activating the drive object
The drive object to be activated has already been commissioned and deactivated again by the
machine manufacturer to market the axis (axes) as an option.
To activate the axis, carry out the following steps:
● Activate the drive object via p0105.
● Enable 2nd axis in the channel machine data.
● Back up the drive machine data via p0971.
● Wait until the data has been written.
● Restart the NC and drives.
<DEVICE>
<list_id>1</list_id>
<name> "Activate the drive" </name>
<SET_ACTIVE>
CNC commissioning
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
<data name = "drive/dc/p105[DO5]">1</data>
Easy Extend
8.6 Examples
249