MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK
Bit 4
When used for measuring or swiveling in JOG, the workpiece reference must be active at
RESET and not cleared (cascaded measuring).
MD24006 $MC_CHSFRAME_RESET_MASK
Bit 4 = 1
MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK
Bit 4 = 0
MD24008 $MC_CHSFRAME_POWERON_MASK
Bit 2
Bit 3
Bit 4
MD24080 $MC_USER_FRAME_POWERON_MASK
Bit 0
Application: Zero offset G5xx, including all rotations, should remain active after Power On.
MD28082 $MC_MM_SYSTEM_FRAME_MASK
Bit 2 = 1
Bit 3 = 1
Bit 4 = 1
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
= 0 Not active
= 1 Remains active
System frame workpiece reference
= 0 Do not delete
= 1 Delete
System frame for workpiece reference remains active after RESET
Do not clear system frame workpiece reference after RESET
System frame rotary table reference (PAROT)
= 0 Do not reset
= 1 Reset
System frame tool reference (TOROT,..)
= 0 Do not reset
= 1 Reset
System frame workpiece reference
= 0 Do not reset
= 1 Reset
= 0 Settable zero offset via power on not active.
=1 Last active settable zero offset remains active after power on if
MD20152 $MC_GCODE_RESET_MODE[7] = 1
Rotary table reference ($P_PARTFRAME)
Tool reference ($P_TOOLFRAME)
Workpiece reference ($P_WPFRAME)
Configuring cycles
Clear system frames after RESET
Active system frames after RESET
Clear system frames after RESET
Reset system frames after power on.
Settings for settable frames.
Setting-up system frames (SRAM)
7.7 Swiveling
139