Commissioning the drive
5.2 Assigning axes
Data backup
The configuration data is backed up after commissioning in the non-volatile memory with the
"Save data" vertical softkey:
Figure 5-14
5.2.2
Example: Setting machine data for an axis/spindle
Axis machine data
After the commissioning in the previous example, the following values are set for the axis
machine data:
Axis machine data
MD30200
MD30230
MD30240
MD31020
MD34200
132
Message to back up data
$MA_NUM_ENCS
$MA_ENC_INPUT_NR
$MA_ENC_TYPE
$MA_ENC_RESOL
$MA_ENC_REFP_MODE
X
Y
Z
1
1
1
1
1
1
1
1
1
2048
2048
2048
1
1
1
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
SP
A
1
1
2
1
1
4
1024
512
1
0
CNC commissioning