Generating user dialogs
1.8 Addressing components
1.8.6
Addressing user data
Addressing user data starts with the path section gud, followed by the GUD name.
For a field, after the name, the required field index should be specified in square brackets.
Example:
<DATA name ="gud/syg_rm[0]"
<OP>"gud/syg_rm[0]" 0 10 </op>
Addressing the global user data
Addressing starts with the path section gud, followed by the specification of the area
CHANNEL. This address section is followed by the specification of the GUD areas:
GUD areas
sgud
mgud
ugud
Then enter the GUD name. If an array is to be addressed, the name is
followed by the array subscript in square brackets.
Example:
<data name ="gud/channel/mgud/syg_rm[0]">1</data>
<op>"gud/channel/mgud/syg_rm[0]" = 5*2 </op>
80
Assignment
Siemens GUD
Machine manufacturer GUD
User GUD
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3