ABB ACS580 Firmware Manual page 379

General purpose drives standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

No.
Name
97 Motor control
97.01
Switching frequency reference
97.02
Minimum switching frequency
97.03
Slip gain
97.04
Voltage reserve
97.05
Flux braking
97.09
Switching frequency mode
97.10
Signal injection
97.11
TR tuning
97.13
IR compensation
97.15
Motor model temperature
adaptation
97.16
Stator temperature factor
97.17
Rotor temperature factor
97.18
Hexagonal field weakening
97.20
U/F ratio
98 User motor parameters
98.01
User motor model mode
98.02
Rs user
98.03
Rr user
98.04
Lm user
98.05
SigmaL user
98.06
Ld user
98.07
Lq user
98.08
PM flux user
98.09
Rs user SI
98.10
Rr user SI
98.11
Lm user SI
98.12
SigmaL user SI
98.13
Ld user SI
98.14
Lq user SI
99 Motor data
99.03
Motor type
99.04
Motor control mode
99.06
Motor nominal current
Type
Range
List
4, 8, 12
List
2, 4, 8, 12
Real
0...200
Real
-4...50
List
0...2
List
0...1
List
0...4
Real
25...400
Real
0.00...50.00
List
0...1
Real
0...200
Real
0...200
List
0...1
List
0...1
List
0...1
Real
0.0000...0.50000
Real
0.0000...0.50000
Real
0.00000...10.00000
Real
0.00000...1.00000
Real
0.00000...10.00000
Real
0.00000...10.00000
Real
0.00000...2.00000
Real
0.00000...100.00000
Real
0.00000...100.00000
Real
0.00...100000.00
Real
0.00...100000.00
Real
0.00...100000.00
Real
0.00...100000.00
List
0...2
List
0...1
Real
0.0...6400.0
Additional parameter data 375
Unit
kHz
kHz
%
%
-
-
-
%
%
-
%
%
-
-
-
p.u.
p.u.
p.u.
p.u.
p.u.
p.u.
p.u.
ohm
ohm
mH
mH
mH
mH
-
-
A
FbEq32
1 = 1 kHz
1 = 1 kHz
1 = 1%
1 = 1%
1 = 1
1 = 1
1 = 1
1 = 1%
100 = 1%
1 = 1
1 = 1%
1 = 1%
1 = 1
1 = 1
1 = 1
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100000 =
1 p.u.
100 = 1 mH
100 = 1 mH
100 = 1 mH
100 = 1 mH
1 = 1
1 = 1
10 = 1 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF