288 Parameters
No.
Name/Value
Timed function 3
Supervision 1
Supervision 2
Supervision 3
Other [bit]
40.58
Set 1 increase
prevention
No
Limiting
Ext PID min lim
Ext PID max lim
Other [bit]
40.59
Set 1 decrease
prevention
No
Limiting
Ext PID min lim
Ext PID max lim
Other [bit]
40.62
PID internal
setpoint actual
-32768.00...
32767.00 PID
customer units
40.91
Feedback data
storage
-327.68...327.67
Description
Bit 2 of
34.01 Timed functions status
Bit 0 of
32.01 Supervision status
Bit 1 of
32.01 Supervision status
Bit 2 of
32.01 Supervision status
Source selection (see
Terms and abbreviations
Prevention of PID integration term increase for PID set 1.
Increase prevention not in use.
The PID integration term is not increased if the maximum
value for the PID output is reached. This parameter is valid
for the PID set 1.
The process PID integration term is not increased when the
output of the external PID has reached its minimum limit. In
this setup, the external PID is used as a source for the
process PID. This parameter is valid for the PID set 1.
The process PID integration term is not increased when the
output of the external PID has reached its maximum limit. In
this setup, the external PID is used as a source for the
process PID. This parameter is valid for the PID set 1.
Source selection (see
Terms and abbreviations
Prevention of PID integration term decrease for PID set 1.
Decrease prevention not in use.
The PID integration term is not decreased if the minimum
value for the PID output is reached. This parameter is valid
for the PID set 1.
The process PID integration term is not decreased when the
output of the external PID has reached its minimum limit. In
this setup, the external PID is used as a source for the
process PID. This parameter is valid for the PID set 1.
The process PID integration term is not decreased when the
output of the external PID has reached its maximum limit. In
this setup, the external PID is used as a source for the
process PID. This parameter is valid for the PID set 1.
Source selection (see
Terms and abbreviations
Displays the value of the internal setpoint. See the control
chain diagram on page 453.
This parameter is read-only.
Process PID internal setpoint.
Storage parameter for receiving a process feedback value eg.
through the embedded fieldbus interface.
The value can be sent to the drive as Modbus I/O data. Set
the target selection parameter of that particular data
(58.101...58.114) to
Feedback data
feedback 1 source
(or
40.09 Set 1 feedback 2
Feedback data
storage.
Storage parameter for process feedback.
(see page 255).
(see page 248).
(see page 248).
(see page 248).
on page 144). -
on page 144). -
on page 144). -
storage. In
40.08 Set 1
source), select
Def/FbEq16
20
21
22
23
No
0
1
2
3
No
0
1
2
3
-
1 = 1 PID
customer unit
-
100 = 1