ABB ACS580 Firmware Manual page 325

General purpose drives standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

No.
Name/Value
76.60
PFC ramp
acceleration time
0.00...1800.00 s
76.61
PFC ramp
deceleration time
0.00...1800.00 s
76.70
Autochange
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
Timed function 1
Timed function 2
Timed function 3
Fixed interval
Description
Defines the acceleration time for the drive motor speed
compensation, when an auxiliary motor is stopped. This ramp
time is also used for the drive motor to accelerate after an
autochange has occurred.
The parameter sets the ramp-up time as seconds from zero
to maximum frequency (not from the previous reference to
the new reference).
Time.
Defines the deceleration time for the drive motor speed
compensation, when an auxiliary motor is started. This ramp
time is also used for the drive motor to decelerate after an
autochange has occurred.
The parameter sets the ramp-up time as seconds from
maximum to zero frequency (not from the previous reference
to the new reference).
Time.
Defines the way the autochange is triggered.
In all cases except
Even
step forward each time the autochange occurs. If the start
order initially is 1-2-3-4, after the first autochange the order
will be 2-3-4-1, etc.
For
Even
wear, the start order will be determined so that the
running times of all motors remain within the defined limit.
Note: Autochange only occurs when the speed of the drive is
below the speed defined by parameter
level.
See also section
Autochange
Autochange disabled.
Rising edge starts the autochange if autochange conditions
are met.
Autochange triggered by the rising edge of digital input DI1
(10.02 DI delayed
status, bit 0).
Autochange triggered by the rising edge of digital input DI2
(10.02 DI delayed
status, bit 1).
Autochange triggered by the rising edge of digital input DI3
(10.02 DI delayed
status, bit 2).
Autochange triggered by the rising edge of digital input DI4
(10.02 DI delayed
status, bit 3).
Autochange triggered by the rising edge of digital input DI5
(10.02 DI delayed
status, bit 4).
Autochange triggered by the rising edge of digital input DI6
(10.02 DI delayed
status, bit 5).
Autochange triggered by timed function 1 (bit 0 of
Timed functions status
(see page 255)).
Autochange triggered by timed function 2 (bit 1 of
Timed functions status
(see page 255)).
Autochange triggered by timed function 3 (bit 2 of
Timed functions status
(see page 255)).
Autochange is done when the interval determined in the
parameter
76.71 Autochange interval
wear, the start order is moved one
76.73 Autochange
on page 103.
has elapsed.
Parameters 321
Def/FbEq16
1.00 s
1 = 1 s
1.00 s
1 = 1 s
Not selected
0
1
2
3
4
5
6
7
34.01
8
34.01
9
34.01
10
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents