No.
Name/Value
Magnetized
Running
Ready ref
At setpoint
Reverse
Zero speed
Above limit
Warning
Fault
Fault (-1)
Fault/Warning
Overcurrent
Overvoltage
Drive temp
Undervoltage
Motor temp
Brake command
Ext2 active
Remote control
Reserved
Timed function 1
Timed function 2
Timed function 3
Reserved
Supervision 1
Supervision 2
Supervision 3
Reserved
Start delay
RO/DIO control
word bit0
RO/DIO control
word bit1
RO/DIO control
word bit2
PFC1
PFC2
PFC3
PFC4
Description
Bit 1 of
06.17 Drive status word 2
Bit 6 of
06.16 Drive status word 1
Bit 2 of
06.11 Main status word
Bit 8 of
06.11 Main status word
Bit 2 of
06.19 Speed control status word
Bit 0 of
06.19 Speed control status word
Bit 10 of
06.17 Drive status word 2
Bit 7 of
06.11 Main status word
Bit 3 of
06.11 Main status word
Inverted bit 3 of
06.11 Main status word
Bit 3 of
06.11 Main status word
word
(see page 154).
Fault
2310 Overcurrent
Fault
3210 DC link overvoltage
Fault
2381 IGBT overload
or
4210 IGBT overtemperature
temperature
or
4310 Excess temperature
temperature difference
has occurred.
Fault
3220 DC link undervoltage
Fault
4981 External temperature 1
temperature 2
has occurred.
Bit 0 of
44.01 Brake control status
Bit 11 of
06.16 Drive status word 1
Bit 9 of
06.11 Main status word
Bit 0 of
34.01 Timed functions status
Bit 1 of
34.01 Timed functions status
Bit 2 of
34.01 Timed functions status
Bit 0 of
32.01 Supervision status
Bit 1 of
32.01 Supervision status
Bit 2 of
32.01 Supervision status
Bit 13 of
06.17 Drive status word 2
Bit 0 of
10.99 RO/DIO control word
Bit 1 of
10.99 RO/DIO control word
Bit 2 of
10.99 RO/DIO control word
Bit 0 of
76.01 PFC status
Bit 1 of
76.01 PFC status
Bit 2 of
76.01 PFC status
Bit 3 of
76.01 PFC status
(see page 155).
(see page 155).
(see page 154).
(see page 154).
(see page 156).
(see page 156).
(see page 155).
(see page 154).
(see page 154).
(see page 154).
OR bit 7 of
06.11 Main status
has occurred.
has occurred.
or
4110 Control board temperature
or
4290 Cooling
or
or
4380 Excess
has occurred.
or
4982 External
(see page 292).
(see page 155).
(see page 154).
(see page 255).
(see page 255).
(see page 255).
(see page 248).
(see page 248).
(see page 248).
(see page 155).
(see page 164).
(see page 164).
(see page 164).
(see page 318).
(see page 318).
(see page 318).
(see page 318).
Parameters 181
Def/FbEq16
6
7
8
9
10
11
12
13
14
15
16
17
18
19
42F1 IGBT
20
21
22
23
24
25...26
27
28
29
30...32
33
34
35
36...38
39
40
41
42
45
46
47
48

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents