General purpose drives standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

No.
Name/Value
36.09
Reset loggers
Done
All
PVL
AL2
36.10
PVL peak value
-32768.00...
32767.00
36.11
PVL peak date
-
36.12
PVL peak time
-
36.13
PVL current at peak
-32768.00...
32767.00 A
36.14
PVL DC voltage at
peak
0.00...2000.00 V
36.15
PVL speed at peak
-30000.00...
30000.00 rpm
36.16
PVL reset date
-
36.17
PVL reset time
-
36.20
AL1 0 to 10%
0.00...100.00%
36.21
AL1 10 to 20%
0.00...100.00%
36.22
AL1 20 to 30%
0.00...100.00%
36.23
AL1 30 to 40%
0.00...100.00%
36.24
AL1 40 to 50%
0.00...100.00%
Description
Resets the peak value logger and/or amplitude logger 2.
(Amplitude logger 1 cannot be reset.)
Reset completed or not requested (normal operation).
Reset both the peak value logger and amplitude logger 2.
Reset the peak value logger.
Reset amplitude logger 2.
Peak value recorded by the peak value logger.
Peak value.
The date on which the peak value was recorded.
Peak occurrence date.
The time at which the peak value was recorded.
Peak occurrence time.
Motor current at the moment the peak value was recorded.
Motor current at peak.
Voltage in the intermediate DC circuit of the drive at the
moment the peak value was recorded.
DC voltage at peak.
Motor speed at the moment the peak value was recorded.
Motor speed at peak.
The date on which the peak value logger was last reset.
Last reset date of the peak value logger.
The time at which the peak value logger was last reset.
Last reset time of the peak value logger.
Percentage of samples recorded by amplitude logger 1 that
fall between 0 and 10%. 100% corresponds to the I
given in the ratings table in chapter Technical data in the
Hardware manual.
Amplitude logger 1 samples between 0 and 10%.
Percentage of samples recorded by amplitude logger 1 that
fall between 10 and 20%.
Amplitude logger 1 samples between 10 and 20%.
Percentage of samples recorded by amplitude logger 1 that
fall between 20 and 30%.
Amplitude logger 1 samples between 20 and 30%.
Percentage of samples recorded by amplitude logger 1 that
fall between 30 and 40%.
Amplitude logger 1 samples between 30 and 40%.
Percentage of samples recorded by amplitude logger 1 that
fall between 40 and 50%.
Amplitude logger 1 samples between 40 and 50%.
Parameters 273
Def/FbEq16
Done
0
1
2
3
0.00
1 = 1
01.01.1980
-
00:00:01
-
0.00 A
1 = 1 A
0.00 V
10 = 1 V
0.00 rpm
See par.
46.01
01.01.1980
-
00:00:01
-
0.00%
value
max
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%