228 Parameters
No.
Name/Value
Motor
potentiometer
PID
Frequency input
Control panel (ref
saved)
Control panel (ref
copied)
Other
28.12
Ext1 frequency ref2
28.13
Ext1 frequency
function
Ref1
Add (ref1 + ref2)
Sub (ref1 - ref2)
Mul (ref1 × ref2)
Min (ref1, ref2)
Max (ref1, ref2)
Description
22.80 Motor potentiometer ref act
potentiometer).
40.01 Process PID output actual
controller).
11.38 Freq in 1 actual value
frequency input).
Panel reference
(03.01 Panel
saved by the control system for the location where the control
returns is used as the reference.
Reference
Ext1 -> Ext2
Panel reference
(03.01 Panel
the previous control location is used as the reference when
the control location changes if the references for the two
locations are of the same type (eg
frequency/speed/torque/PID); otherwise, the actual signal is
used as the new reference.
Reference
Ext1 -> Ext2
Source selection (see
Terms and abbreviations
Selects Ext1 frequency reference source 2.
For the selections, and a diagram of reference source
selection, see parameter
Selects a mathematical function between the reference
sources selected by parameters
and
28.12 Ext1 frequency
frequency
ref1.
Signal selected by
28.11 Ext1 frequency ref1
frequency reference 1 as such (no function applied).
The sum of the reference sources is used as frequency
reference 1.
The subtraction
([28.11 Ext1 frequency
frequency
ref2]) of the reference sources is used as
frequency reference 1.
The multiplication of the reference sources is used as
frequency reference 1.
The smaller of the reference sources is used as frequency
reference 1.
The greater of the reference sources is used as frequency
reference 1.
(output of the motor
(output of the process PID
(when DI5 or DI6 is used as a
reference, see page 149)
Ext1 reference
Ext2 reference
Active reference
Inactive reference
t
reference, see page 149) for
Ext1 reference
Ext2 reference
Active reference
Inactive reference
t
on page 144). -
28.11 Ext1 frequency
ref1.
28.11 Ext1 frequency ref1
ref2. See diagram at
28.11 Ext1
is used as
ref1] -
[28.12 Ext1
Def/FbEq16
15
16
17
18
19
Zero
Ref1
0
1
2
3
4
5

Hide quick links: