328 Parameters
No.
Name/Value
ABB standard
(vector)
96.05
Macro active
ABB standard
Hand/Auto
Hand/PID
3-wire
Alternate
Motor
potentiometer
PID
Panel PID
PFC
ABB standard
(vector)
96.06
Parameter restore
Done
Restore defaults
Clear all
Reset all fieldbus
settings
Reset home view
Reset end user
texts
Description
ABB standard (vector) macro (see page 62). For vector motor
control.
Shows which control macro is currently selected. See chapter
Control macros
(page 59) for more information.
To change the macro, use parameter
Factory macro (see page 60). For scalar motor control.
Hand/Auto macro (see page 70).
Hand/PID macro (see page 72).
3-wire macro see page 60).
Alternate macro see page 66).
Motor potentiometer macro (see page 68).
PID macro (see page 74).
Panel PID macro (see page 76).
PFC macro (see page 78).
ABB standard (vector) macro (see page 61). For vector motor
control.
Restores the original settings of the control program, ie.
parameter default values.
Note: This parameter cannot be changed while the drive is
running.
Restoring is completed.
Restores all editable parameter values to default values,
except
• motor data and ID run results
• I/O extension module settings
• end user texts, such as customized warnings and faults,
and the drive name
• control panel/PC communication settings
• fieldbus adapter settings
• control macro selection and the parameter defaults
implemented by it
• parameter
95.20 HW options word 1
defaults implemented by it.
Restores all editable parameter values to default values,
except
• end user texts, such as customized warnings and faults,
and the drive name
• control macro selection and the parameter defaults
implemented by it
• parameter
95.20 HW options word 1
defaults implemented by it
• group
49 Panel port communication
Restores all fieldbus and communication related settings to
default values.
Note: Fieldbus, control panel and PC tool communication are
interrupted during the restore.
Restores the home view layout back to show the values of the
default parameters defined by the control macro in use
Restores all end user texts to default values, including the
drive name, contact info, customized fault and warning texts,
PID unit and currency unit.
96.04 Macro
select.
and the differentiated
and the differentiated
parameters.
Def/FbEq16
17
ABB
standard
1
2
3
11
12
13
14
15
16
17
Done
0
8
62
32
512
1024