7360 ISAM FX-4 shelf cabling
Figure 199
External CO alarm cable for 7360 ISAM FX-4
Supplier
label
For a description of the CO external alarm connector pinning, see your Nokia
representative.

18.7 BITS interface connections

The 7360 ISAM FX-4 requires six wire-wrappable pins for the BITS clock timing
connection. BITS timing signals will be supplied using two twisted pair cables (22
AWG solid copper conductors with overall shield and drain wire, Belden 1175A or
equivalent). One cable will connect to the 3 wire-wrap pins for NT-A, and the other
will connect to the 3 wire-wrap pins for NT-B.
See Figure
For a description of the BITS cable connector pinning, see Appendix 25.
18.8 ToD/PPS connector
The 7360 ISAM FX-4 requires an RJ-45 connector cable for the Time of Day and
PPS signal connection located on the NT card. See Figure
connector.