Installing a 7360 ISAM FX-8 shelf
Procedure 52
Use the following procedure to install or replace a fan unit.
1
2
3
4
5
6
254
To install or replace a fan unit
Unpack and inspect the fan unit visually for physical damage.
If anything is missing or damaged, notify the transportation carrier and Nokia immediately.
Photograph all the damaged equipment. Keep all the inspection and packing documents as
a reference.
Warning — Possibility of equipment damage.
Do not install damaged equipment, as it can adversely affect other
equipment.
Put on the antistatic wrist strap and connect it to a grounding point.
Verify if the fan unit type is correct for the rack configuration. See Table 10.
Verify the mounting position of the fan unit; see Figure 128.
Remove the fan unit from its shipping packaging and inspect it for damage. If damaged, do
not mount the fan unit but notify the transportation carrier and Nokia immediately.
3HH-12893-AAAA-TCZZA
ANSI Hardware Installation Manual
DRAFT
Issue: 09