Grounding Cable Connection On 7360 Isam Fx-12 - Nokia 7360 Intelligent Services Access Manager FX Series Hardware Installation Manual

Ansi
Hide thumbs Also See for 7360 Intelligent Services Access Manager FX Series:
Table of Contents

Advertisement

7360 ISAM FX-12 shelf cabling
Figure 79
Procedure 33
Use the following procedure to connect the grounding cable.
1
2
3
172

Grounding cable connection on 7360 ISAM FX-12

Ground cable connector
To connect the grounding cable
Route the grounding cable to the right side of the shelf and up to the middle of the shelf.
Connect the dual-lug to the grounding cable connection point as shown in Figure 79.
Danger — Possible risk of personal injury or damage to equipment due
to inaccurate or faulty ground cabling.
Inaccurate grounding connection can cause electric shock or equipment
damage when the rack power is switched on.
Note — The grounding cable nuts should be tightened with a torque of
13.28 to 17.7 lbf-in. (1.5 to 2.0 N.m).
STOP. This procedure is complete.