Figure 197 Mounting Of Power Cable Screws And Safety Cover On; 7360 Isam Fx-4 - Nokia 7360 Intelligent Services Access Manager FX Series Hardware Installation Manual

Ansi
Hide thumbs Also See for 7360 Intelligent Services Access Manager FX Series:
Table of Contents

Advertisement

7360 ISAM FX-4 shelf cabling
Figure 197
3
4
5
6
7
8
352
Mounting of power cable screws and safety cover on

7360 ISAM FX-4

Remove the screws from the power terminals; see Figure 197.
Danger — If the following sequence is not followed exactly, there can
be a possible fire hazard.
Guide the power cables through the cable guide and connect them to the power terminals as
follows; see Figure
196
showing the cables connected:
Note — The RET A and RET B connections are on a common ground.
first connect the BATRET cables RET A and RET B
then connect the battery cables BAT A and BAT B
Tighten the nuts back on the power terminals with a torque of 13.28 to 17.7 lbf-in. (1.5 to 2.0
N.m).
Place the safety cover back in its location and fasten the screws.
Turn on the A and B power from the power distribution frame to the rack.
Verify that the BAT A and BAT B LEDs are green.
3HH-12893-AAAA-TCZZA
ANSI Hardware Installation Manual
DRAFT
22398
Issue: 09

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7360 isam fx-16

Table of Contents