Figure 34 Fan Unit Handles - Nokia 7360 Intelligent Services Access Manager FX Series Hardware Installation Manual

Ansi
Hide thumbs Also See for 7360 Intelligent Services Access Manager FX Series:
Table of Contents

Advertisement

ANSI Hardware Installation Manual
Figure 34
7
8
9
Issue: 09
Fan unit handles
Handle
If the system is active, be aware of the maximum time (5 minutes) that the fans are allowed
to be out of operation.
Danger — If the fans are not operating, the system may start a fire. Shut
down shelves if fans are nonoperational for longer than 5 minutes.
Install the new fan unit:
i
Gently insert the fan unit into the fan area until the backplane connectors are fully
mated.
ii
If a fan filter was installed, re-insert the fan filter.
iii
Replace the fan unit cover and secure the cover and the fan unit by tightening the
captive screws.
In the same way, install the fan units of other shelf units, if any.