Installing a 7360 ISAM WM shelf
The drip tray can be shipped factory installed in the rack, but can also be ordered as
a separate unit for installation or replacement on site.
Procedure 90
Use this procedure to install a drip tray or to replace a drip tray below an existing 7360 ISAM WM
rack configuration.
1
2
3
394
For safety reasons, it is critical that the spacing
Caution 1 —
between the shelf bracket and the drip tray bracket does not
exceed a distance of 2.36 in. (60 mm).
Drip trays must be installed beneath each
Caution 2 —
7360 ISAM WM shelf in a rack, including below the bottom
shelf of a rack when mounted on combustible flooring surfaces.
For example, carpet.
To install a drip tray below a 7360 ISAM WM shelf
Verify the drip tray type is correct for the rack configuration. See Figure
correct installation position.
Remove the drip tray unit from its shipping packaging and inspect the part for damage. If
damaged, do not install the drip tray, but instead notify the transportation carrier and Nokia
immediately.
Mount the drip tray in the mounting position shown in Figure 230. Attach the drip tray with
screws to the rack uprights.
3HH-12893-AAAA-TCZZA
ANSI Hardware Installation Manual
DRAFT
232
to verify the
Issue: 09