Installing a 7360 ISAM FX-8 shelf
Procedure 50
Use this procedure to mount a 7360 ISAM FX-8 shelf horizontally in a 23 in. rack.
1
2
3
4
244
horizontal shelf mount kit containing:
shelf horizontal brackets (x2)
12-24 × 1/2 in. (12.7 mm) screws
6-32 × 3/8 in. (9.53 mm) screws
vertical shelf mount kit containing:
rack adapter brackets
pre-assembled top cross bracket, rear skirt and front skirt
pre-assembled shelf horizontal mount bracket and air intake baffle/drip tray
intumescent panel
top baffle
12-24 × 1/2 in. (12.7 mm) screws
M3 × 5/16 in. (8 mm) screws
M3 × 9/16 in. (14 mm) screws
M3 × 9/16 in. (14 mm) screws
12-24 × 1/2 in. (12.7 mm) screws
fan unit (BFAN-E))
8 AWG power lug
general facilities card, if replacing (NGFC-H)
cables:
50-pin micro DSUB connector
DB-9 connector
RJ-45 connector
6-pin wire-wrap right angle header connector
120-pin FCI power blade connector
To mount the 7360 ISAM FX-8 shelf horizontally in a 23 in. rack
Unpack and inspect the shelf visually for physical damage.
If anything is missing or damaged, notify the transportation carrier and Nokia immediately.
Photograph all the damaged equipment. Keep all the inspection and packing documents as
a reference.
Warning — Possibility of equipment damage.
Do not install damaged equipment, as it can adversely affect other
equipment.
Put on the antistatic wrist strap and connect it to a grounding point.
Verify the 7360 ISAM FX-8 shelf mounting locations on the rack; see Figure 128.